| CR1V 6 PB02 |
6 |
±12 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 6 PB03 |
6 |
±12 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 6 PB04 |
6 |
±20 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 15 PB02 |
15 |
±30 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 15 PB03 |
15 |
±30 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 15 PB04 |
15 |
±51 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 25 PB02 |
25 |
±50 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 25 PB04 |
25 |
±85 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 50 PB03 |
50 |
±100 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 50 PB04 |
50 |
±150 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|
| CR1V 75 PB05 |
75 |
±180 |
5 |
2.5V |
±1.0 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
more...
|