| AN3V 10 PB50 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Open loop current sensors use the simplest implementation of the Hall effect. They provide the smallest, lightest, and most cost effective current measurement solution while also having very low power consumption
more...
|
| AN3V 16 PB50 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 5V Electrical Measuring Analog Module Current Voltage Small AC Current Transducer 10A 16A 20A 32A 40A 50A
more...
|
| AN3V 20 PB50 |
20 |
±50 |
5 |
2.5±2V |
±1 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
ASIC current sensors are integrated circuits designed to measure current using Hall effect technology. They operate by passing a current through a conductor, generating a magnetic field that is detected by a sensor. The output signal is then amplified and corrected using an ASIC, which enhances accuracy and stability.
more...
|
| AN3V 32 PB50 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Open loop current sensor small size wideMeasurement range 10A 16A 20A 32A 40A 50A low power consumption Frequency bandwidth 250kHz based on PCB mounting
more...
|
| AN3V 40 PB50 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
A Hall effect current sensor is an electronic device used to measure electric current by detecting the magnetic field generated around a current-carrying conductor.
more...
|
| AN3V 50 PB30 |
50 |
±125 |
3.3 |
1.65±1.15V |
+1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall Effect Current Sensor 3.3V Low Power 4.3kV Isolation current sensor module for power electronics for New Energy Industrial Automation
more...
|
| AN3V 50 PB50 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 5V current sensor for Servo Motor 4.3kV Isolation for Industrial Drive BMS and industrial control system
more...
|
| AN3V 80 PB55 |
80 |
±200 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current sensor is an electronic device that measures the flow of electric current in a conductor and converts this measurement into a usable output signal, such as voltage or digital data. This output can be used for monitoring, control, or protection in various applications, including industrial automation, electric vehicles, and renewable energy systems.
more...
|
| AN3V 100 PB55 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall effect current sensor supply voltage 5V high sensitivity low noise for combining manifolds for PCB board mounting Electronic Equipment
more...
|
| AN3V 120 PB55 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current sensor detects and measures the electric current passing through a conductor. It turns the current into a quantifiable output, such as a voltage, current, or digital signal, which may be utilised in a variety of applications for monitoring, control, or protection.
more...
|
| AN3V 10 PB30 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 10 PB31 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 10 PB51 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB30 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB31 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB51 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB30 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB31 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB51 |
20 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB30 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB31 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB51 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB30 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB31 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB51 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 50 PB31 |
50 |
±125 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 50 PB51 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB35 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB31 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB51 |
80 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB35 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB31 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB51 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB35 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB31 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB51 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 150 PB55 |
150 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 180 PB55 |
180 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 200 PB55 |
200 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 150 PB35 |
150 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 180 PB35 |
180 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 200 PB35 |
200 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|