| AN3V 10 PB50 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Very low power consumption open loop current sensors
more...
|
| AN3V 16 PB50 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Supply voltage 5V Electrical Measuring Analog Module Small AC Current Transducer 10A 16A 20A 32A 40A 50A
more...
|
| AN3V 20 PB50 |
20 |
±50 |
5 |
2.5±2V |
±1 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- ASIC current sensors for HVDC application area
more...
|
| AN3V 32 PB50 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Small size PCB mounting open loop current sensor
more...
|
| AN3V 40 PB50 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Electronic components hall effect current sensor
more...
|
| AN3V 50 PB30 |
50 |
±125 |
3.3 |
1.65±1.15V |
+1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall effect current sensor for new energy industrial automation
more...
|
| AN3V 50 PB50 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Supply voltage 5V current sensor for Servo Motor
more...
|
| AN3V 80 PB55 |
80 |
±200 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensor for renewable energy systems
more...
|
| AN3V 100 PB55 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall effect current sensor supply voltage 5V high sensitivity low noise for combining manifolds Electronic Equipment
more...
|
| AN3V 120 PB55 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Current sensor for monitoring, control, or protection.
more...
|
| AN3V 10 PB30 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
High permeability Hall effect transducer measure AC/DC current for EV charging pile
more...
|
| AN3V 10 PB31 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
HLSR current transducer in power electronics, motor drives, and renewable energy systems.
more...
|
| AN3V 10 PB51 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
SMD PCB mount current sensor for industrial
more...
|
| AN3V 16 PB30 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Professional hall effect current sensor manufacturer for fast switching applications
more...
|
| AN3V 16 PB31 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size renewable energy current transducer 10A-120A for high efficiency SMPS
more...
|
| AN3V 16 PB51 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Industrial current transducer alternative supplier current transducer for VFD systems
more...
|
| AN3V 20 PB30 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Cost effective Hall effect current sensor for AI server PSU
more...
|
| AN3V 20 PB31 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current Sensor 20A 3.3V 2.5us PCB HLSR-P
more...
|
| AN3V 20 PB51 |
20 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
HLSR Industrial Current Sensors
more...
|
| AN3V 32 PB30 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
The different types of available current sensors and their typical use cases
more...
|
| AN3V 32 PB31 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current sensor selection guide for motor control applications and how to test current sensor
more...
|
| AN3V 32 PB51 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall effect sensor ensure for battery efficiency and protecting against current overloads
more...
|
| AN3V 40 PB30 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How to replace a hall effect transducer for current measurement
more...
|
| AN3V 40 PB31 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size open cloop supply voltage 3.3V linearity ±0.5 for 250khz for industrial applications
more...
|
| AN3V 40 PB51 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Electronic components PCB board mounting open cloop hall current sensor for SMPS and UPS
more...
|
| AN3V 50 PB31 |
50 |
±125 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage+3.3V open loop current sensor based on Hall effect PCB installation
more...
|
| AN3V 50 PB51 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Good Iinear variable differential current sensor active speed sensor wide measure range10A 16A 20A 32A 40A 50A 80A 100A 120A
more...
|
| AN3V 80 PB35 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How integrated current sensors can open new perspectives for system
more...
|
| AN3V 80 PB31 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
UPS power HLSR current sensor price
more...
|
| AN3V 80 PB51 |
80 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size height 8.7mm open loop 250kHz bandwidth supply voltage+5V for MPPT
more...
|
| AN3V 100 PB35 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 3.3V hall effect current sensor for combining manifolds
more...
|
| AN3V 100 PB31 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
High precision magnetic sensor interfacing ASIC
more...
|
| AN3V 100 PB51 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How integrated current sensors can open new perspectives for system design.
more...
|
| AN3V 120 PB35 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall current sensor 80-200A AC/DC Input/output suitable for industrial power supply with an aperture of ±0.3 mm
more...
|
| AN3V 120 PB31 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall current sensor 3.3V AC/DC 10A 16A 20A 32A 40A 50A 80A 100A 120A electrical Current Transducer analog output
more...
|
| AN3V 120 PB51 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current transducer sensor 120A range 80mV/A sensitivity PCB mount for motor drives UPS
more...
|
| AN3V 150 PB55 |
150 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary current direction marking diagram open loop bidirectional current sensor for general power electronics
more...
|
| AN3V 180 PB55 |
180 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Customized current automotive grade current sensor for circuit breaker
more...
|
| AN3V 200 PB55 |
200 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop current sensor transducer 200A
more...
|
| AN3V 150 PB35 |
150 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Industrial combining manifold current measurement hall sensor alternative to LA17P S05 open loop current transducer for industrial converters
more...
|
| AN3V 180 PB35 |
180 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
250kHz bandwidth 2.5µs fast response time current transducer alternative HLSR
more...
|
| AN3V 200 PB35 |
200 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
200A Ultra thin HLSR 8.7mm height galvanic isolated current detector -40 to 105℃ wide temperature