| CN2A 40 PB01 |
40 |
±110 |
±12...15 |
±20mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010
- Premium Made in China dc hall effect current tranducer
more...
|
| TR1V 0.01 H00 |
10mA |
15mA |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Current Sensors: Types, Key Parameters, Performance Comparison, and Common Applications Current sensors are critical components in a wide range of electrical and electronic systems, ensuring that equipment and gadgets operate safely and efficiently. We will examine current sensors in this article, including their kinds, variables to consider when choosing a current sensor, performance comparison, and applications.
more...
|
| TR1V 0.02 H00 |
20mA |
30mA |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Fast Response time high frequency AC current monitoring sensor supply voltage ±12V ±15V, primary nominal rms current 10mA 20mA 50mA 100mA 200mA
more...
|
| TR1V 0.05 H00 |
50mA |
75mA |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Low current consumption through hole hall current sensor supply voltage ±12V ±15V, rated output voltage 5V for Industrial control
more...
|
| TR1V 0.1 H00 |
100mA |
150mA |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Used to detect leakage current or residual current in electrical systems. It converts tiny currents into measurable signals through electromagnetic induction or magnetic modulation principles, enabling electrical safety monitoring.
more...
|
| TR1V 0.2 H00 |
200mA |
250mA |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
An energy and leakage current monitoring current sensor for abnormality detection in electrical appliances
more...
|
| CN2A 25 PB02 |
25 |
±55 |
±12...15 |
±25mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| CN2A 40 PB02 |
40 |
±90 |
±12...15 |
±40mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| CN2A 50 PB02 |
50 |
±90 |
±12...15 |
±50mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010