TR1V 0.01 H00 |
0.01 |
0.015 |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
TR1V 0.02 H00 |
0.02 |
0.03 |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
TR1V 0.05 H00 |
0.05 |
0.075 |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
TR1V 0.1 H00 |
0.1 |
0.15 |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
TR1V 0.2 H00 |
0.2 |
0.25 |
±12...15 |
5V |
±1.0 |
50 |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Ac current sensor based on transformer technology
- DC voltage output
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High accuracy
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR7V 0.005 H00 |
0.005 |
±0.007 |
±15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø12 |
|
KF2EDG 3.81MM 4P |
- Current sensor based on fluxgate technology
- Output voltage
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR2V 0.01 H00 |
0.01 |
±0.015 |
±12...15 |
±5V |
+1.0 |
DC |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL 94-V0.(Black)
- High linearity
- Very low zero temperature drift
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
FR5V 0.01 H00 |
0.01 |
±0.015 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø40.5 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL94-V0(Black)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR2V 0.02 H00 |
0.02 |
±0.03 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø20 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL 94-V0.(Black)
- High linearity
- Very low zero temperature drift
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
FR5V 0.02 H00 |
0.02 |
±0.03 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø40.5 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL94-V0(Black)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR2V 0.05 H00 |
0.05 |
±0.075 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL 94-V0.(Black)
- High linearity
- Very low zero temperature drift
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
FR5V 0.05 H00 |
0.05 |
±0.075 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø40.5 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL94-V0(Black)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR2V 0.1 H00 |
0.1 |
±0.15 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL 94-V0.(Black)
- High linearity
- Very low zero temperature drift
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
FR5V 0.1 H00 |
0.1 |
±0.15 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø40.5 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL94-V0(Black)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
FR2V 0.3 H00 |
0.3 |
±0.36 |
±12...15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø20.0 |
|
JK2EDG-5.08-4P |
- Current sensor based on fluxgate technology
- Output Voltage
- Insulating plastic case recognized according to UL 94-V0.(Black)
- High linearity
- Very low zero temperature drift
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
FR7V 0.01 H00 |
0.01 |
±0.017 |
±15 |
±5V |
±1.0 |
DC |
-10~70 |
Ø12 |
|
KF2EDG 3.81MM 4P |
- Current sensor based on fluxgate technology
- Output voltage
- Insulating plastic case recognized according to UL 94-V0(Blue)
- High linearity
- Very low zero temperature drift
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010