| CM3A 500 H00 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
Molex 6410 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensor CT measures direct current flow using the hall effect renewable energy, electric vehicles, and power monitoring
more...
|
| CM3A 500 H01 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
JST B3P VH |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall current measurement device 500A low current consumption
more...
|
| CM4A 1000 H00 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
Molex 6410 |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Closed-loop current transducers supplier low voltage measuring 1000A
more...
|
| CM4A 1000 H03 |
1200 |
±1800 |
±24 |
±300...450mA |
±0.4 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- High accuracy wide applications fileds closed-loop hall effect current sensor 1000A supply voltage ±24
more...
|
| CM4A 1000 H05 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Professional current transducer supplier for rail transit system
more...
|
| VN2A 25 P01 |
5mA |
7mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Single power supply:+24V
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Voltage sensor is a device used for detecting and measuring voltage. It converts the measured voltage into a manageable signal, enabling monitoring, control and protection functions.
more...
|
| VN2A 25 P00 |
10mA |
±14mA |
±15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Insulating plastic case recognized according to UL94-V0.
- No insertion loss.
- Small size.
- High accuracy.
- Very good linearity.
- Very low offset drift over temperature.
- High output frequency bandwidth.
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Voltage sensor measures and monitors voltage levels within an object, detecting either AC or DC voltage. It inputs voltage and outputs various forms such as switches, analog voltage signals, current signals, or audible signals.
more...
|
| VN2A 25 P02 |
10mA |
±14mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Voltage sensor used for measuring and monitoring the voltage level in an object. The voltage sensor can determine the level of either alternating current voltage or direct current voltage.
more...
|
| VN2A 400 PB02 |
400V |
±400V |
±12 |
±5V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +12V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Measure the level of alternating current and/or the level of direct current voltage PCB hole Φ1.2 Output nominal rms current 25mA
more...
|
| VN2A 800 PB00 |
800V |
±1400V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Voltage sensor ±12V ±15V ±0.6% accuracy closed loop hall effect for Industrial drives
more...
|
| VN2A 800 PB01 |
800V |
±1400V |
24 |
4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +24V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
High quality new and original automobile current sensor voltage sensor
more...
|
| VN2A 1100 PB00 |
1100V |
±1500V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Supply voltage 12V 15V Primary nominal rms voltage 800V 1100V voltage sensor
more...
|
| VN2A 1100 PB03 |
1100V |
±1500V |
±15 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL 94-V0
- Small size
- High accuracy
- Supply voltage:±15V
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| VN2A 1100 PB20 |
1100V |
±1100V |
±12 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
XH-3A |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Industrial voltage sensor for power supply monitoring system
more...
|
| VN3A 6400 M00 |
6400V |
±9600V |
±15...24 |
±80mA |
±1.0 |
|
-20~70 |
NA |
|
M5 threaded bolts |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL 94-V0
- Mutual shielding between the primary and secondary
- Primary side resistance R1 integrated into the sensor
- High accuracy
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Voltage sensor used for monitoring voltage levels in electrical grids and substations
more...
|
| VN4A 500 M15 |
500V |
±750V |
±15...24 |
50mA |
±1.0 |
14 |
-40~85 |
NA |
|
M5 thread screw |
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Galvanic insulation between the primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- EN 50155:2017
Good linearity ±0.5% voltage transducer for single phase industrial inverter monitoring
more...
|
| VN4A 750 M15 |
750V |
±1125V |
±15...24 |
50mA |
±1.0 |
14 |
-40~85 |
NA |
|
M5 thread screw |
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Galvanic insulation between the primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- EN 50155:2017
No insertion loss primary busbar ±12V ±24V current sensor for battery management system
more...
|
| VN4A 1500 M15 |
1500V |
±2250V |
±15...24 |
50mA |
±1.0 |
14 |
-40~85 |
NA |
|
M5 thread screw |
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Galvanic insulation between the primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- EN 50155:2017
Optimized delay time high precision voltage sensor for battery chargers
more...
|
| VN4A 2000 M15 |
2000V |
±3000V |
±15...24 |
50mA |
±1.0 |
14 |
-40~85 |
NA |
|
M5 thread screw |
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Galvanic insulation between the primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- EN 50155:2017
Supply voltage 15V 24V wide frequency bandwidth voltage transducer