CM3A 500 H00 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
Molex 6410 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
CM3A 500 H01 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
JST B3P VH |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
CM4A 1000 H00 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
Molex 6410 |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
CM4A 1000 H03 |
1200 |
±1800 |
±24 |
±300...450mA |
±0.4 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
CM4A 1000 H05 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
CM6A 1000 B00 |
1000 |
±2000 |
±24 |
±200...400mA |
±0.4 |
150 |
-40~85 |
Primary copper busbar |
|
4×M5 threaded bolts |
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50155: 2007, UL508:2013
more...
|
VN2A 25 P01 |
5mA |
7mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Single power supply:+24V
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 25 P00 |
10mA |
±14mA |
±15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Insulating plastic case recognized according to UL94-V0.
- No insertion loss.
- Small size.
- High accuracy.
- Very good linearity.
- Very low offset drift over temperature.
- High output frequency bandwidth.
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
VN2A 25 P02 |
10mA |
±14mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 400 PB02 |
400V |
±400V |
±12 |
±5V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +12V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 800 PB00 |
800V |
±1400V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 800 PB01 |
800V |
±1400V |
24 |
4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +24V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 1100 PB00 |
1100V |
±1500V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 1100 PB03 |
1100V |
±1500V |
±15 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL 94-V0
- Small size
- High accuracy
- Supply voltage:±15V
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN2A 1100 PB20 |
1100V |
±1100V |
±12 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
XH-3A |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
VN3A 6400 M00 |
6400V |
±9600V |
±15...24 |
±80mA |
±1.0 |
|
-20~70 |
NA |
|
M5 threaded bolts |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL 94-V0
- Mutual shielding between the primary and secondary
- Primary side resistance R1 integrated into the sensor
- High accuracy
- Good linearity
- Very low offset drift over temperature
- Resistant to strong external interference
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|