Split core hall effect current sensor measure DC, AC and complex current wave forms with galvanic isolation. The advantages include low cost, small size, lightweight and low power consumption and are especially advantageous when measuring high currents. This sensor can be clamped on to the existing cable without interruption of the primary circuit.
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
| Product No | Primary nominal RMS current(A) | Measuring range(A) | Supply voltage (V) | Secondary output | Accuracy(%) | Output bandwidth(kHz) | Operating Temp.(°C) | Copper busbar(mm) | PCB | Others |
|---|---|---|---|---|---|---|---|---|---|---|
| HK1A 200 H00 | 200 | ±240 | 12 | 4...20mA | ±1.0 | DC | -25~85 | Ø41.3 | 2EDGV-3.81-4P | |
![]() HK1A 200 H00
|
||||||||||
| HK1A 400 H00 | 400 | ±480 | 12 | 4...20mA | ±1.0 | DC | -25~85 | Ø41.3 | 2EDGV-3.81-4P | |
![]() HK1A 400 H00
|
||||||||||
| HK1V 1000 H00 | 1000 | ±2000 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 1000 H00
Split core open loop hall effect CT 1000A more... |
||||||||||
| HK1V 1000 H01 | 1000 | ±2000 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 1000 H01
Measure AC/DC split core Hall current sensor 200A 400A 500A 600A 800A 1000A 2000A linearity and accuracy ±1 % more... |
||||||||||
| HK1V 200 H00 | 200 | ±400 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 200 H00
High voltage power distribution current sensor 200A current transducer supply voltage more... |
||||||||||
| HK1V 200 H01 | 200 | ±400 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 200 H01
High precision primary nominal rms current wide measure rang 200A-2000A DC/AC 5V output voltage industrial grade current sensor more... |
||||||||||
| HK1V 2000 H00 | 2000 | ±4000 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 2000 H00
Working voltage current measuring sensor split core current sensor 2000A more... |
||||||||||
| HK1V 2000 H01 | 2000 | ±4000 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 2000 H01
Hot selling open type current transducer high quality sensor 200-2000A current transducer split core more... |
||||||||||
| HK1V 400 H00 | 400 | ±800 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 400 H00
Industrial current sensor for power supply monitoring system more... |
||||||||||
| HK1V 400 H01 | 400 | ±800 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 400 H01
Hall efect current sensor AC DC split core current sensor supply voltage ±12V ±15V current transformer specifications 400A/5V more... |
||||||||||
| HK1V 600 H00 | 600 | ±1200 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 600 H00
Split core wide measure range 200A-2000A galvanic isolation current sensor for energy monitoring more... |
||||||||||
| HK1V 600 H01 | 600 | ±1200 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 600 H01
Design innovation current sensor adopting a split structure,convenient for installation and adaptable to various scenarios. Installation can be completed quickly without power interruption. more... |
||||||||||
| HK1V 800 H00 | 800 | ±1600 | ±12...15 | ±4V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 800 H00
Industrial Grade DC/AC Current consumption 25mA compatible split core current sensor for inverter more... |
||||||||||
| HK1V 800 H01 | 800 | ±1600 | ±12...15 | ±5V | ±1.0 | 10 | -40~85 | Ø40.5 | 15EDGVC-3.5-04P | |
![]() HK1V 800 H01
Strong anti-interference capability Frequency band width can reach from DC to 40kHz, capable of accurately capturing high-frequency current harmonics, with an output error of less than 0.5% more... |
||||||||||
| HK3A 100 H20 | ±100 | ±100 | 12 | 4...20mA | ±1.0 | DC | -25~85 | Ø21.6 | KF2EDGV-3.81-4P | |
![]() HK3A 100 H20
|
||||||||||
| HK3A 50 H20 | ±50 | ±50 | 12 | 4...20mA | ±1.0 | DC | -25~85 | Ø21.6 | KF2EDGV-3.81-4P | |
![]() HK3A 50 H20
|
||||||||||
| HK3V 100 H20 | ±100 | ±200 | ±12...15 | ±4V | ±1.0 | DC | -25~85 | Ø21.6 | KF2EDGV-3.81-4P | |
![]() HK3V 100 H20
|
||||||||||
| HK3V 50 H20 | ±50 | ±100 | ±12...15 | ±4V | ±1.0 | DC | -25~85 | Ø21.6 | KF2EDGV-3.81-4P | |
![]() HK3V 50 H20
|
||||||||||
| HK4V 2000 H00 | 2000 | ±4000 | ±15 | 4V | ±1.0 | DC...40 | -40~85 | 112mm x 30mm | 2EDG-4P-3.81 | |
![]() HK4V 2000 H00
|
||||||||||
| HK4V 3000 H00 | 3000 | ±5500 | ±15 | 4V | ±1.0 | DC...40 | -40~85 | 112mm×30mm | 2EDG-4P-3.81 | |
![]() HK4V 3000 H00
|
||||||||||
| HK4V 5000 H00 | 5000 | ±6000 | ±15 | 5V | ±1.0 | DC...40 | -40~85 | 112mm x 30mm | 2EDG-4P-3.81 | |
![]() HK4V 5000 H00
|
||||||||||
| HK5V 1000 H20 | ±1000 | ±1500 | ±12...15 | ±4V | ±1.0 | 20 | -25~85 | 16mm×64mm | 2EDG-4P-3.81 | |
![]() HK5V 1000 H20
|
||||||||||
| HK5V 200 H20 | ±200 | ±300 | ±12...15 | ±4V | ±1.0 | 20 | -25~85 | 16mm×64mm | 2EDG-4P-3.81 | |
![]() HK5V 200 H20
|
||||||||||
| HK5V 400 H20 | ±400 | ±600 | ±12...15 | ±4V | ±1.0 | 20 | -25~85 | 16mm×64mm | 2EDG-4P-3.81 | |
![]() HK5V 400 H20
|
||||||||||
| HK5V 600 H20 | ±600 | ±900 | ±12...15 | ±4V | ±1.0 | 20 | -25~85 | 16mm×64mm | 2EDG-4P-3.81 | |
![]() HK5V 600 H20
|
||||||||||
| HK5V 800 H20 | ±800 | ±1200 | ±12...15 | ±4V | ±1.0 | 20 | -25~85 | 16mm×64mm | 2EDG-4P-3.81 | |