Product No | Primary nominal RMS current(A) | Measuring range(A) | Supply voltage (V) | Secondary output | Accuracy(%) | Output bandwidth | Operating Temp.(°C) | Copper busbar(mm) | PCB | Others |
---|---|---|---|---|---|---|---|---|---|---|
CR1V 15 PB01 | 15 | ±45 | 5 | 2.5±1.875V | ±0.7 | 200 | -40~85 | NA | + | |
CR1V 15 PB01<ul><li>Closed loop(compensated)current sensor using the Hall effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion losses</li><li>Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010</li></ul> more... |
||||||||||
AN5V 5 PB00 | 5 | ±15 | ±12...15 | ±4V | ±1.0 | 50 | -40~85 | NA | + | |
AN5V 5 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN5V 10 PB00 | 10 | ±30 | ±12...15 | ±4V | ±1.0 | 50 | -40~85 | NA | + | |
AN5V 10 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN3V 10 PB50 | 10 | ±25 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 10 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN5V 15 PB00 | 15 | ±45 | ±12...15 | ±4V | ±1.0 | 50 | -40~85 | NA | + | |
AN5V 15 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN3V 16 PB50 | 16 | ±40 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 16 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN5V 20 PB00 | 20 | ±60 | ±12...15 | ±4V | ±1.0 | 50 | -40~85 | NA | + | |
AN5V 20 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN3V 20 PB50 | 20 | ±50 | 5 | 2.5±2V | ±1 | 250 | -40~105 | NA | + | |
AN3V 20 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN5V 25 PB00 | 25 | ±75 | ±12...15 | ±4V | ±1 | 50 | -40~85 | NA | + | |
AN5V 25 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN3V 32 PB50 | 32 | ±80 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 32 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 40 PB50 | 40 | ±100 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 40 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN5V 50 PB00 | 50 | ±150 | ±12...15 | ±4V | ±1.0 | 50 | -40~85 | NA | + | |
AN5V 50 PB00<ul><li>Open loop current sensor using the Hall Effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>Standards:</li><li>EN50178: 1997</li><li>IEC 61010-1: 2000</li><li>UL 508: 2010</li></ul> more... |
||||||||||
AN1V 50 PB20 | 50 | ±50 | 5 | 2.5±2V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB20<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 50 PB21 | 50 | ±50 | 5 | 2.5±2V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB21<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 50 PB22 | 50 | 0~50 | 5 | 0.55+4V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB22<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 50 PB23 | 50 | 0~50 | 5 | 0.55+4V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB23<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 50 PB30 | 50 | ±50 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB30<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 50 PB31 | 50 | ±50 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 50 PB31<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 50 PB30 | 50 | ±50 | 3.3 | 1.65±1.15V | +1.0 | 250 | -40~150 | NA | + | |
AN3V 50 PB30<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+3.3V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 50 PB50 | 50 | ±125 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 50 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 80 PB50 | 80 | ±200 | 5 | 2.5±2V | +1.0 | 250 | -40~105 | NA | + | |
AN3V 80 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB20 | 100 | ±100 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN1V 100 PB20<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB21 | 100 | ±100 | 5 | 2.5±2V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 100 PB21<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB22 | 100 | 0-100 | 5 | 0.55+4V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 100 PB22<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB23 | 100 | 0-100 | 5 | 0.55+4V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 100 PB23<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB30 | 100 | ±100 | 3.3 | 1.65+1.32V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 100 PB30<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 100 PB31 | 100 | ±100 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~150 | NA | + | |
AN1V 100 PB31<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 100 PB50 | 100 | ±250 | 5 | 2.5±2V | ±1.0 | 250 | -40~105 | NA | + | |
AN3V 100 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN3V 120 PB50 | 120 | ±300 | 5 | 2.5±2V | ±1.0 | 120 | -40~105 | NA | + | |
AN3V 120 PB50<ul><li>Open loop current sensor using the Hall effect.</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Supply voltage:+5V</li><li>Small size.</li><li>h=8.7mm</li><li>Standards:</li><li>IEC 60664-1:2020</li><li>IEC 61800-5-1:2022</li><li>IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 150 PB20 | 150 | ±150 | 5 | 2.5±2V | ±1.0 | 250 | -40~125 | NA | + | |
AN1V 150 PB20<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 150 PB21 | 150 | ±150 | 5 | 2.5±2V | ±1.0 | 250 | -40~125 | NA | + | |
AN1V 150 PB21<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 150 PB23 | 150 | 0-150 | 5 | 0.55+4V | ±1.0 | 250 | -40~125 | NA | + | |
AN1V 150 PB23<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 150 PB30 | 150 | ±150 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~125 | NA | + | |
AN1V 150 PB30<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 150 PB31 | 150 | ±150 | 3.3 | 1.65+1.32V | ±1.0 | 250 | -40~125 | NA | + | |
AN1V 150 PB31<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB20 | 200 | ±200 | 5 | 2.5±2V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB20<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB21 | 200 | ±200 | 5 | 2.5±2V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB21<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB22 | 200 | 0-200 | 5 | 0.55+4V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB22<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB23 | 200 | 0-200 | 5 | 0.55+4V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB23<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB30 | 200 | ±200 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB30<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
AN1V 200 PB31 | 200 | ±200 | 3.3 | 1.65±1.32V | ±1.0 | 250 | -40~85 | NA | + | |
AN1V 200 PB31<ul><li>Open loop current sensor using the Hall effect.</li><li>ASIC Technology.</li><li>Maintain output proportional to changes in the power supply(include offset and sensitivity).</li><li>Galvanic separation between primary and secondary.</li><li>Insulating plastic case recognized according to UL 94-V0.</li><li>No insertion losses.</li><li>Small size.</li><li>Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |