Product description
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Specification
Primary nominal RMS current (A) |
200 |
Measuring range (A) |
±600 |
Supply voltage (V) |
5 |
Secondary output |
2.5±0.625V |
Accuracy (%) |
±1.0 |
Output bandwidth |
50 |
Operating temperature (°C) |
-40~105 |
Copper busbar (mm) |
20.5x10.5 mm |
PCB |
|
Others |
Molex 5045-04A |