Product No | Primary nominal RMS current(A) | Measuring range(A) | Supply voltage (V) | Secondary output | Accuracy(%) | Output bandwidth | Operating Temp.(°C) | Copper busbar(mm) | PCB | Others |
---|---|---|---|---|---|---|---|---|---|---|
CM3A 500 H00 | 500 | ±800 | ±15...24 | ±100mA | ±0.5 | 100 | -40~85 | Ø30.2 | ||
CM3A 500 H00<ul><li>Closed loop (compensated) current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
CM3A 500 H01 | 500 | ±800 | ±15...24 | ±100mA | ±0.5 | 100 | -40~85 | Ø30.2 | ||
CM3A 500 H01<ul><li>Closed loop (compensated) current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
CM4A 1000 H00 | 1000 | ±2100 | ±15...24 | ±200mA | ±0.3 | 150 | -40~85 | Ø38 | ||
CM4A 1000 H00<ul><li>Closed loop(compensated)current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
CM4A 1000 H03 | 1000 | ±1800 | ±24 | ±300mA | ±0.4 | 150 | -40~85 | Ø38 | ||
CM4A 1000 H03<ul><li>Closed loop(compensated)current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
CM4A 1000 H05 | 1000 | ±2100 | ±15...24 | ±200mA | ±0.3 | 150 | -40~85 | Ø38 | ||
CM4A 1000 H05<ul><li>Closed loop(compensated)current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
CM6A 1000 B00 | 1000 | ±2000 | ±24 | ±200mA | ±0.4 | 150 | -40~85 | Primary copper busbar | ||
CM6A 1000 B00<ul><li>Closed loop(compensated)current sensor using the Hall effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:EN50155: 2007, UL508:2013</li></ul> more... |
||||||||||
VN2A 25 P01 | 5mA | 7mA | 24 | ±25mA | ±0.8 | -40~85 | NA | + | ||
VN2A 25 P01<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Single power supply:+24V</li><li>No insertion loss</li><li>Small size</li><li>High accuracy</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>High output frequency bandwidth</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 25 P00 | 10mA | ±14mA | ±15 | ±25mA | ±0.6 | -40~85 | NA | + | ||
VN2A 25 P00<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect.</li><li>Insulating plastic case recognized according to UL94-V0.</li><li>No insertion loss.</li><li>Small size.</li><li>High accuracy.</li><li>Very good linearity.</li><li>Very low offset drift over temperature.</li><li>High output frequency bandwidth.</li><li>Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010</li></ul> more... |
||||||||||
VN2A 25 P02 | 10mA | ±14mA | ±12 | ±25mA | ±0.6 | -40~85 | + | |||
VN2A 25 P02<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>No insertion loss</li><li>Small size</li><li>High accuracy</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>High output frequency bandwidth</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 400 PB02 | 400V | ±500V | ±12 | ±25mA | ±0.6 | -40~85 | NA | |||
VN2A 400 PB02<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Small size</li><li>High accuracy</li><li>Supply voltage +12V</li><li>Very good linearity</li><li>Very low offset drift over temperature.</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 800 PB00 | 800V | ±1400V | ±12...15 | ±25mA | ±0.6 | -40~85 | NA | |||
VN2A 800 PB00<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Small size</li><li>High accuracy</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 800 PB01 | 800V | ±1400V | 24 | 4V | ±0.6 | -40~85 | NA | |||
VN2A 800 PB01<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Small size</li><li>High accuracy</li><li>Supply voltage +24V</li><li>Very good linearity</li><li>Very low offset drift over temperature.</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 1100 PB00 | 1100V | ±1500V | ±12...15 | ±25mA | ±0.6 | -40~85 | NA | |||
VN2A 1100 PB00<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Small size</li><li>High accuracy</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 1100 PB03 | 1100V | ±1500V | ±15 | ±25mA | ±0.6 | -40~85 | NA | |||
VN2A 1100 PB03<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Small size</li><li>High accuracy</li><li>Supply voltage:±15V</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN2A 1100 PB20 | 1100V | ±1500V | ±12 | ±25mA | ±0.6 | -40~85 | NA | |||
VN2A 1100 PB20<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Small size</li><li>High accuracy</li><li>Very good linearity</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
VN3A 6400 M00 | 6400V | ±9600V | ±15...24 | ±80mA | ±1.0 | -20~70 | M5 threaded bolts | |||
VN3A 6400 M00<ul><li>Closed loop (compensated) voltage sensor using the Hall Effect</li><li>Insulating plastic case recognized according to UL 94-V0</li><li>Mutual shielding between the primary and secondary</li><li>Primary side resistance R1 integrated into the sensor</li><li>High accuracy</li><li>Good linearity</li><li>Very low offset drift over temperature</li><li>Resistant to strong external interference</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |