Product No | Primary nominal RMS current(A) | Measuring range(A) | Supply voltage (V) | Secondary output | Accuracy(%) | Output bandwidth | Operating Temp.(°C) | Copper busbar(mm) | PCB | Others |
---|---|---|---|---|---|---|---|---|---|---|
CN2A 40 PB01 | 40 | ±110 | ±12...15 | ±20mA | ±0.5 | 200 | -40~85 | NA | + | |
CN2A 40 PB01<ul><li>Closed loop (compensated) current sensor using the Hall Effect</li><li>Galvanic separation between primary and secondary</li><li>Insulating plastic case recognized according to UL94-V0</li><li>Very good linearity</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>No insertion loss</li><li>Standards:</li><li>IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010</li></ul> more... |
||||||||||
TR1V 0.01 H00 | 0.01 | 0.015 | ±12...15 | ±5V | ±0.5 | 50 | -10~70 | Ø20.0 | ||
TR1V 0.01 H00<ul><li>Ac current sensor based on transformer technology</li><li>DC voltage output</li><li>Insulating plastic case recognized according to UL 94-V0(Blue)</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
TR1V 0.02 H00 | 0.02 | 0.03 | ±12...15 | ±5V | ±0.5 | 50 | -10~70 | Ø20.0 | ||
TR1V 0.02 H00<ul><li>Ac current sensor based on transformer technology</li><li>DC voltage output</li><li>Insulating plastic case recognized according to UL 94-V0(Blue)</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
TR1V 0.05 H00 | 0.05 | 0.075 | ±12...15 | ±5V | ±0.5 | 50 | -10~70 | Ø20.0 | ||
TR1V 0.05 H00<ul><li>Ac current sensor based on transformer technology</li><li>DC voltage output</li><li>Insulating plastic case recognized according to UL 94-V0(Blue)</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
TR1V 0.1 H00 | 0.1 | 0.15 | ±12...15 | ±5V | ±0.5 | 50 | -10~70 | Ø20.0 | ||
TR1V 0.1 H00<ul><li>Ac current sensor based on transformer technology</li><li>DC voltage output</li><li>Insulating plastic case recognized according to UL 94-V0(Blue)</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |
||||||||||
TR1V 0.2 H00 | 0.2 | 0.25 | ±12...15 | ±5V | ±0.5 | 50 | -10~70 | Ø20.0 | ||
TR1V 0.2 H00<ul><li>Ac current sensor based on transformer technology</li><li>DC voltage output</li><li>Insulating plastic case recognized according to UL 94-V0(Blue)</li><li>High accuracy</li><li>Very low offset drift over temperature</li><li>Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010</li></ul> more... |